Accessible drives
Tools: Phillips PH0 / (+) No. 0 screw driver

12.6.1.1 Preliminary steps

"Disabling or suspending BitLocker functionality" on page 67
Ê
"Shutting down the server" on page 51
Ê
"Disconnecting power cords" on page 52
Ê
"Getting access to the component" on page 53
Ê
"Removing the fan box" on page 168
Ê

12.6.1.2 Removing the ODD carrier

Figure 161: Removing the ODD carrier
Ê Pull the locking latch upward to unlock the ODD carrier.
V
CAUTION!
Save the ODD dummy module for future use.
Always replace dummy modules into unused drive bays to comply with
applicable EMC regulations and satisfy cooling requirements.
272