Table 34 Device Status Dialog Box Fields (continued)
Field
Status
Software Version
Dialog Refresh
Device Refresh
Reset Device
Time Last Seen
Error Count,
Error Code,
POTS State, POTS Init,
Ring State, Loop State,
Performance Data,
Debug Data,
Actor Data
Configuring and Managing Analog Line Card Ports
Purpose
The state of the port when it was last polled by the NCP.
Status does not indicate the current state of dial tone at the
port. The NCP polls each port for its status every 30
seconds.
Values:
OnCall— The port was in use when last polled by the NCP.
Idle — The port was available for a call when last polled by
the NCP.
Unknown — The port has not communicated with the call
processor during the previous five minutes. Indicates a likely
problem with the port.
The version of software currently installed on the line card
and used by the Digital Signal Processors (DSPs).
Specifies how often to renew the information that appears
in the Status dialog box.
Forces the port to send a status message to the Call
Processor. (A port sends a status message to the Call
Processor every 30 seconds.)
Reboots the port, which resets communications with the
Call Processor and receives a new download of its operating
software.
If a call is in progress on the port, resetting the port
disconnects the call.
A time stamp that identifies the date and time the line card
port communicated with the Call Processor.
Advanced diagnostic data for use only by a qualified service
person.