Toshiba Strata CTX28 Programming Manual page 74

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Installation
WinCTX Offline Programming CTX R2.21 MH108
4. Select a Region Code: Click the down arrow and highlight a country. The Region Code is the same
country list in Program 915-04.
5. Select the Access Folder: This is where the "default.dat" file will be stored. The empty default folder is
"C:/WINCTX/SM/".
If you want to use a different folder that contains a default.dat file or create a new "default.dat" file,
click Browse. The Searching Access Folder window displays. Select a folder, then click Set.
To edit an existing "default.dat" file, select the folder that contains the "default.dat" file which should
be edited.
6. Click the Start button. The window title shows "WinCTX is running."
7. If you click "No," the second screen displays (see previous page).
If a "default.dat"file exists in the selected folder,
the window (shown right) displays:
Click Yes to load the "default.dat" file into
WinCTX. WinCTX shows "Restoring," as it loads
the existing default.dat.
If a "default.dat" file is not in the selected folder,
the "Load default.dat?" screen does not appear and
WinCTX immediately displays the "WinCTX is
running" screen. You can still connect to WinCTX
to create a new default.dat file in the selected
folder by continuing with the following steps.
8. With WinCTX running, log on to WinAdmin.
• Enter CTX IP/Name (IP address): 127.0.0.1 or your local PC's IP address.
• Enter a Community Name (CTX default is "communityName").
9. Click the Connect Now button. WinAdmin should connect to WinCTX and operate exactly as if it were
connected to a CTX system.
In the PC Local Area Connection Property Settings, you may need to set the PC Internet Protocol
Note
(TCP/IP) properties to use the following IP address: 192.168.254.251. Subnet mask: 255.255.255.0.
10.Make your offline programming changes from WinAdmin.
11. When you are done programming, select Operation > Data Backup. Click the Back Up button. When
you see "Completed Successfully," it is done. This will create a new "default.dat" file that contains your
programming changes.
Important!
12.Log out of WinAdmin and then bring up the WinCTX application screen and click the Stop button to
stop WinCTX (see
13.To transfer the WinCTX database to a CTX system, locate the "default.dat" file in the folder previously
selected in Step 4.
14.Transfer the "default.dat" file to a SmartMedia card (progdata folder) in the CTX, either locally or
remotely, and then restore the data to the CTX using the system initialization procedure (Program 900
level 1). See
3-24
Data changes will not be stored in the default.dat file unless you backup your data using
WinAdmin.
"Stopping
WinCTX").
Chapter
10–Operation,
"900 CTX
Restart."