Toshiba Strata CTX28 Programming Manual page 395

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Table 13-33
Programs 321~324 (continued)
Button
Sequence
321-02
Number Prefix
A7
C‚yq
, n,
321-03
Number Verification
A7"
C‚yq
, n,
321-04
Default Number 2
A7#
C‚yq
C‚yq
, n,
,
322
CNIS Presentation
And Special Number
Assignment
"
C‚yq
,
322-00
OLG Number
C‚yq
n,
322-01
Source Type
A7
C‚yq
, n,
322-02
Source Number
A7
C‚yq
, n,
322-03
Special Number
Assignments
A7"
C‚yq
C‚yq
, n,
,
323
CBC Service
" "
C‚yq
,
323-00
Channel Group
C‚yq
n,
323-01
Index
A7
C‚yq
, n,
323-02
Type of Service
A7
C‚yq
, n,
323-03
Facility Code
A7"
C‚yq
, n,
Strata CTX Programming - Part 3: Telephone Button Programming 6/04
Value(s)
n =
Up to 10 digits
n =
1. Enable
2. Disable
n =
Up to 10 digits
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
1. Primary DN (0~99999)
2. Group CO (1~128)
3. Pooled Line Group
(1~128)
n =
Up to 5 digits
GCO and POOL:
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
Up to 7 digits
n =
1~32 (CTX100)
1~48 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
0~32 (CTX100)
0~48 (CTX670 Basic)
0~128 (CTX670 Exp.)
n =
1. No Data (default)
2. POTS
3. FX
4. Tie line (Enbloc)
5. Tie line (Cut throuogh)
6. Intra LATA Out WATS
7. Banded Out WATS
8. Inter LATA Out WATS
9. INWATS
n =
00~31
Telephone Button Programming
Summary
Enter the prefix telephone number for which a DID number will be
appended to create a User Identified telephone number. This number
may or may not be a billed number, but is used for Caller ID at the
distant end and could be used for returning your call.
Specify whether the number provided should be screened by the
PSTN before the call is to proceed.
Enter the second telephone number to use by default when
originating a call. This is the number that the PSTN has registered for
billing purposes. The second number is for BRI only
When calls are sent to the PSTN with Calling Number Identification
Service (CNIS), the CTX can supply special CNIS information as part
of the Setup Message. This program may be used for sending a
unique number based on the source directing the call to the Strata
CTX PRI.
OLG Number.
Specify the type of circuit used for outgoing calls: 1- PDN; 2- GCO; 3-
Pooled Line.
Specify the number of the source type selected (PDN, GCO or
Pooled Line).
Note
Entries for this field depend on the Destination Type chosen.
There are no default values for this field (default = no value).
PDN: 0~99999
GCO: 1~128
POOL: 1~128
Specify the number to be sent when calling out from the source (max.
seven digits). This number is appended to Program 321 FB02.
Note
Destination Type and Destination must be entered before a
DID number can be assigned.
To accomplish CBC services, each facility needs to be defined, its
related Line Group assigned and minimum and maximum values for
the services provided. These service parameters may be set for three
different time zones, thus allowing fewer or more services of different
types at different times of the day.
Enter the Channel Group Number.
Enter the CBC Service Index, or click one of the following buttons:
List – view a summary list of programmed Trunks.
Create – Assign a new Trunk with default settings.
Select the CBC Service Type.
Note
To delete CBC, set this field to
Enter the supplied Facility code value from the PSTN. If no data is
entered in this field, any previously entered data is deleted.
300 Series Programs
1: No Data
.
13-71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx670Strata ctx100-sStrata ctx100

Table of Contents