Toshiba Strata CTX28 Programming Manual page 172

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Trunks
300 Trunk Assignment
F
IELD
Line No.
01 Day1 Destination Type
02 Day2 Destination Type
03 Night Destination Type
Day1 Destination Digits
Day2 Destination Digits
Night Destination Digits
04 MOH Source
6-12
D
ESCRIPTION
Enter the trunk equipment number. Equipment numbers are required when
assigning a new trunk to the system. It can also be used to display the equipment
location of existing trunks.
Example: If a line should be assigned to an RCOU in cabinet shelf 5, slot 2, circuit 3,
enter 050203.
Possible values: xx = cabinet 01~07; yy =slot 01~10; zz = circuit 01~08 or Channel
01~24 (CTX670).
xx = cabinet 01; yy =slot 01~08; zz = circuit 01~24 or Channel
(CTX100)
(default = no value).
Cabinet numbers:
CTX28 equipment assignments are fixed. See Program 100.
CTX100 – Select 01 for Base and Expansion cabinet.
CTX670 – Select 01 for Base and 02~07 respectively for each Expansion
cabinet.
Slot numbers:
CTX28 equipment assignments are fixed. See Program 100.
CTX100 – Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670 – Select 01~08 for Base slots and 01~10 for Expansion slots.
Select Destination Type for each.
Possible values: : No Data (default), Dialing Digits, DISA, Built-in Modem, or Night
Bell
No Data – no destination will ring when the line rings into the system.
Dialing Digits – assigns the line to ring the directory number or access code
defined in the "Destination Digits" assignment
DSIA – assigns the line to ring in as a DSIA call. DSIA dial tone will be returned
to the caller.
Modem – assigns the line to ring the remote maintenance modem on the CTX
processor. Used to call into the system with a CTX WinAdmin PC and modem.
Night Bell – Assigns the line to cause the night relay to pulse (one-sec.close/3-
sec.open)
Enter Destination, Directory Number or Access Codes for each, only if Dialing Digits
is selected as Destination Type.
If Dialing Digits is the Destination Type, enter the Directory Number that the line
should ring.If the line should ring over external page, enter #31xx, where xx is
the external Page group number.
If the default page access code #31 was changed, use the new page access
code as the leading digits.
Line access codes and network routing numbers can also be entered to route
incoming calls back out to a public or private network number.
Possible values: Up to 32 digits (default = no value)
Select the MOH source for Analog DIT Trunk. The Scroll key must be used to select
MOH sources indicated by 10 or higher.
Possible values: External1~15 (default = External1)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04