Table 13-35
Programs 500~577 (continued)
Button
Sequence
513-04
Abandoned Call
Record Output
A7#
C‚yq
, n,
513-05
Display Transferred
Call Records
A7$
C‚yq
, n,
514
SMDR for OLG
Assignment
$ #
C‚yq
,
514-00
OLG
C‚yq
n,
514-01
SMDR Record
Display
A7
C‚yq
, n,
514-02
Outgoing Records
A7"
C‚yq
, n,
514-03
Outgoing Records
A7"
C‚yq
, n,
515
View BIOU Control
Relay Assignment
$ $
C‚yq
,
515-00
BIOU (1 or 2)
C‚yq
n,
515-01
BIOU Relay 1 or 5
A7
C‚yq
, n,
515-02
BIOU Relay 2 or 6
A7
C‚yq
, n,
515-03
BIOU Relay 3 or 7
A7"
C‚yq
, n,
515-04
BIOU Relay 4 or 8
A7#
C‚yq
, n,
13-80
Value(s)
n =
1. Enable
2. Disable (default)
n =
1. Source (default)
2. Destination
C‚yq
,
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
1. Enable (default)
2. Disable
n =
1. Enable (default)
2. Disable
C‚yq
,
n =
1. Source (default)
2. Destination
C‚yq
,
n =
1 or 2
n =
1. Not Use (default)
2. Ext Paging
3. Night Bell
4. Night Relay
5. Door Lock
C‚yq
,
Enable record generation for abandoned calls. Incoming SMDR must
be turned on. Abandoned call records will be generated whether or
not incoming SMDR has been set.
Select whether to charge a transferred call to the source or
destination party.
This command assigns SMDR parameters for OLGs.
Specify the OLG for which to set SMDR parameters.
Enable SMDR Record Display.
Enable to generate records for outgoing calls. SMDR Record Display
must be on.
Enable to apply the SMDR record of a transferred call to its source or
its destination.
This assignment is used to view functions of the four control relays on
each BIOU PCB set in Program 105 12 Night Relay and 18 Night Bell
Relay; Program 508 Door Lock Control Assignment; and Program
503 19 BGM Mute Relay. The system allows up to two BIOU PCBs to
provide a total of eight control relays. The control relays can be
configured as an external BGM mute control, Night Bell control, Night
Mode Control, and Door Lock Control.
Notes
BIOU-1 relays are identified as Control Relays 1~4.
BIOU-2 relays are identified as Control Relays 5~8.
Enter the BOIU PCB number.
Note
BIOU 1 and BIOU 2 are assigned in Program 100 - Card
Assignment.
View the function of BIOU1, control relay 1 or BIOU2, control relay 5:
View the function of BIOU1, control relay 2 or BIOU2, control relay 6:
View the function of BIOU1, control relay 3 or BIOU2, control relay 7:
View the function of BIOU1, control relay 4 or BIOU2, control relay 8:
NOT USE – if the relay is not used.
PAGE MUTE – External BGM mute control activates during an
external page (see
"Program 503" on page
NIGHT BELL – Night Bell control activates during the system
Night Mode only when incoming CO lines ring (see
102" on page
12).
NIGHT RELAY – Night Mode Control activates continuously
during the system Night Mode (see
DOOR LOCK – Door Lock Control activates when a telephone's
Door Unlock button is pressed (see
Strata CTX Programming - Part 3: Telephone Button Programming 6/04
Summary
75).
"Program
"Program 105" on page
"Program 508" on page
18).