Charging Output Check (Dr350S) - Suzuki DR350 Service Manual

Dr350; dr350s
Hide thumbs Also See for DR350:
Table of Contents

Advertisement

OR3505 8-28
When
the
engine speed
increases
and
the
load
decreases. the battery
charge
voltage
will increase
due to
the
generated voltage
by the
generator.
The battery
will
continue
to
be
charged
by the
gener-
ated voltage
until
the
battery
voltage (voltage between
@
and
@
)
reaches the
value set of the control
circuit
in the
regulator,
then
a signal
from the
circuit will
flow to the
SeR.
When the
SeR goes
"
ON
".
O
and
@will
become
conductive
,
hence the
voltage
does
not
cha rge
the battery but
returns to
the
generator.
When
the battery
voltage falls
.
the
signal
to the
seA
will be
out otf
,
causing
the
SeR
to
go
" OFF"
.
As a
result,
the
generated voltage will start
to
charge
the battery
once again
.
Due to the
repetition
of
the above
operation of
the regulator. the battery
voltage will
be maintained
constant,
preventing
o vercharging
of the
battery_
------------
--,
-~
,
u
-5
e
-
c
0
u
I
L _______________ _
INSPECTION
CHARGING OUTPUT CHECK
Remove the left frame
cover
_
Start the
engine
and keep it running at
5 000
rl
min
with
the lighting
swtich turned ON (High position).
Using the pocket tester
,
measure the DC
voltage
between
the
battery
®
terminal
and
e
terminal.
If the tester reads
under
13.0V
or over
15.
5V,
check
the
AC
generator
no-
load
performance and
regulator/rectifier
.
NOTE:
When
making this test,
be sure
that
the battery
is
in
fully-
charged
condition.
STD charging output:
13.0
-15.5V
(DC) at 5 000
r/min