Charging Output Check; Ac Generator No-Load Performance - Suzuki RG250 Service Manual

Table of Contents

Advertisement

6-3
ELECTRICAL SYSTEM
INSPECTION
CHARGING OUTPUT CHECK
Remove the seat.
Start the engine and keep it
running
at 5000
r/min
with
dimmer
switch turned
H
I position.
Using
the pocket
tester, measure the DC voltage
between the battery
terminal
EB
and
e
.
If
the tester
reads
under
13.5V
or over
15.5V,
check the AC generator
no
~
load
performance
and
regulator/
rectifier
.
NOTE:
When making this test,
be
sure that the
battery is fully-charged condition.
STD charging
output
09900-25002
13.5
-
15.5V
(DC)
at 5,000
r/
min
.
Pocket tester
AC GENERATOR NO-LOAD PERFORMANCE
Remove the
left frame cover
seat and fuel
tank.
Disconnect
the couplers
from the
regulatorl
rectifier.
Start the engine and keep it running at 5
000
r/
min
.
Using
the pocket
tester,
measure the AC voltage
between
the
three
yellow
lead
wires.
If
the
tester reads under 34V
,
the AC
generator
is faulty.
STD No-load performance
More than
34V
(AC)
at
5000
ri
min
09900
-25002
Pocket tester
Regulator
Rectifier
,
' - - . - - - '
Battery;
o
IG
. swi
t ch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents