Port Mirroring Configuration - Interlogix IFS NS3601-24P User Manual

24-port gigabit ethernet switches
Table of Contents

Advertisement

Port Mirroring Configuration

Configure port Mirroring on this page. This function provide to monitoring network traffic that forwards a copy of each incoming or
outgoing packet from one port of a network Switch to another port where the packet can be studied. It enables the manager to keep
close track of switch performance and alter it if necessary.
• To debug network problems, selected traffic can be copied, or mirrored, to a mirror port where a frame analyzer can be
attached to analyze the frame flow.
• The Managed Switch can unobtrusively mirror traffic from any port to a monitor port. You can then attach a protocol analyzer or
RMON probe to this port to perform traffic analysis and verify connection integrity.
The traffic to be copied to the mirror port is selected as follows:
All frames received on a given port (also known as ingress or source mirroring).
All frames transmitted on a given port (also known as egress or destination mirroring).
IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual
Figure 4-4-5 Port Mirror application
82

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ifs ns3601-4sGe-dssg-244Ge-dssg-244-poeNs3601-24p/4s

Table of Contents