<timeout>: Time before error-disabled ports are reenabled (30-86400 seconds, 0 disables)
(default: Show recovery timeout)
Default Setting:
Disable
Example:
Set STP recovery value in 30 sec.
SWITCH/>stp recovery 30

STP Status

Description:
Show STP Bridge status.
Syntax:
STP Status [<msti>] [<port_list>]
Parameters:
: STP bridge instance no (0-7, CIST=0, MSTI1=1, ...)
<msti>
<port_list>: Port list or 'all', default: All ports
Default Setting:
Disable
Example:
Show STP Bridge status.
SWITCH/>stp status
CIST Bridge STP Status
Bridge ID
: 80:00-00:30:4F:24:04:D1
Root ID
: 80:00-00:30:4F:24:04:D1
Root Port
: -
Root PathCost: 0
Regional Root: 80:00-00:30:4F:24:04:D1
Int. PathCost: 0
Max Hops
: 20
TC Flag
: Steady
TC Count
: 0
TC Last
: -
Port
Port Role
---------
--------------
14
DesignatedPort Forwarding 128 20000

STP MSTI Priority

Description:
Set or show the CIST/MSTI bridge priority.
Syntax:
STP Msti Priority [<msti>] [<priority>]
Parameters:
: STP bridge instance no (0-7, CIST=0, MSTI1=1, ...)
<msti>
<priority> : STP bridge priority (0/16/32/48/.../224/240)
Default:
MSTI Bridge Priority
----
---------------
CIST
128
MST1 128
MST2 128
MST3 128
State
Pri PathCost Edge P2P Uptime
----------
---
--------
339
User's Manual of NS3601-24P/4S Series
----
---
-------------
Yes
Yes 0d 00:10:32