SWITCH/>ip ping 192.168.0.21
PING server 192.168.0.21
60 bytes from 192.168.0.21: icmp_seq=0, time=0ms
60 bytes from 192.168.0.21: icmp_seq=1, time=0ms
60 bytes from 192.168.0.21: icmp_seq=2, time=0ms
60 bytes from 192.168.0.21: icmp_seq=3, time=10ms
60 bytes from 192.168.0.21: icmp_seq=4, time=0ms
Sent 5 packets, received 5 OK, 0 bad
IP DNS
Description:
Set or show the DNS server address.
Syntax:
IP DNS [<ip_addr>]
Parameters:
<ip_addr>: IP address (a.b.c.d), default: Show IP address
Default Setting:
0.0.0.0
Example:
Set DNS IP address:
SWITCH/>ip dns 168.95.1.1

IP DNS Proxy

Description:
Set or show the IP DNS Proxy mode.
Syntax:
IP DNS_Proxy [enable|disable]
Parameters:
enable : Enable DNS Proxy
disable: Disable DNS Proxy
Default Setting:
disable
Example:
Enable DNS proxy function:
SWITCH/>ip dns_proxy enable

IPv6 AUTOCINFIG

Description:
Set or show the IPv6 AUTOCONFIG mode.
Syntax:
IP IPv6 AUTOCONFIG [enable|disable]
Parameters:
enable : Enable IPv6 AUTOCONFIG mode
disable: Disable IPv6 AUTOCONFIG mode
IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual