CHAPTER 2
System Setup
Figure 4. Outdoor Unit Installation
Complete the following steps to install the outdoor unit:
1.
Fasten the Wireless Modem to the aluminum mast (provided
by Adcon) using the supplied ring clamp.
2.
Fasten the antenna to the Wireless Modem.
3.
Plug the proper end of the communication cable into the
lower connector of the Wireless Modem.
4.
Secure the mast in its place on the roof.
5.
Run the cable to the indoor unit.
Note: The cable supplied to connect the outdoor unit to the A850
Telemetry Gateway is 30 m long and cannot be extended,
but special low-attenuation cables with a total length of up
to 90 m can be provided upon request by Adcon.
In addition, if you are upgrading an existing A730SD installation,
you can use the low attenuation coaxial cable provided with the
A730SD's high gain roof antenna.