Figure 213. Sensor type - Internal sensor settings - Internal type
Conversion settings
Figure 214. Sensor type - Conversion settings - Internal
•
Sensor table - if you want to use a non-linear sensor, select
one of the sensor tables already defined in the menu item
"Sensor Tables" for conversion/linearization; if you intend to
use a linear sensor, select "none";
Figure 215. Sensor type - Conversion settings - Sensor table - Internal
Note: If a sensor table is entered for a non-linear sensor, the fol-
lowing entries for Linear input value refer to the output val-
ues of the linearization table and not to the voltage
measured on the analog pin!
•
Linear input value - entry of the minimum and maximum value
of the range within which the sensor delivers measurements;