Comtech EF Data CDM-700 Installation And Operation Manual page 180

High speed satellite modem
Table of Contents

Advertisement

CDM-700 High Speed Satellite Modem
Remote Control
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Faults and
N/A
8 bytes
Status
Description of Arguments
to Query
Query only.
Unit returns the current fault and status codes for the Unit (hardware), Modulator, Demodulator, and
Interfaces, where:
a = Unit Faults:
0 = No Faults
1 = Framer FPGA Not Loaded
2 = 1.5 Volt Supply
3 = 1.5 Volt Supply (Intfc 1)
4 = 1.5 Volt Supply (Intfc 2)
5 = 3.3 Volt Supply
6 = 5.0 Volt Supply
7 = 12.0 Volt Supply
8 = -12.0 Volt Supply
9 = 18.0 Volt Supply
A = Flash Load
B = FPGA Load (FEC 1)
bb = Tx Faults:
00 = No Faults
01 = Modulator 1.5 Volt Supply
02 = Modulator FPGA Not Loaded
03 = Symbol Rate PLL
04 = Synthesizer Lock
05 = Digital Clock Mgmt Lock
06 = I & Q Activity
07 = Modulator Temperature
08 = Modulator Filters
09 = Cable Slot 1 Port 1
0A = Cable Slot 1 Port 2
0B = Cable Slot 2 Port 1
0C = Cable Slot 2 Port 2
0D = AIS Slot 1 Port 1
0E = AIS Slot 1 Port 2
0F = AIS Slot 2 Port 1
0G = AIS Slot 2 Port 2
0H = ASI Slot 1 Clock
0I = ASI Slot 2 Clock
Response to
Command
N/A
C = FPGA Load (FEC 2)
D = FPGA Load (Interface 1)
E = FPGA Load (Interface 2)
F = 192MHz PLL Fault
G = Ext Reference PLL Fault
H = Framer FPGA Temperature
I = Framer Temperature
J = Cooling Fans
K = Interface 1
L = Interface 2
M = 1:1 Redundancy Switch
0J = PECL Slot 1 FIFO
0K = PECL Slot 2 FIFO
0L = Reserved
0M = Rserved
0N = Reserved
0O = Reserved
0P = Reserved
0Q = Reserved
0R = Reserved
0S = Reserved
0T = Reserved
0U = Reserved.
0V = Serdes Slot 1 to Framer
0W = Serdes Slot 2 to Framer
0X = Serdes Modulator to FEC 1
0Y = Serdes Modulator to FEC 2
0Z = Serdes FEC 1 to Framer
10 = Serdes FEC 2 to Framer
11 = Serdes Framer to Modulator
13= GBEI
CABLE SLOT 1
14 = GBEI CABLE SLOT 22
11–30
Revision 5
MN/CDM700.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
FLT?
FLT=aabbccde (see
description for details of
arguments
d=0
NO Change in fault status
since last poll.
D=1
Change in fault status
since last poll.
E=0
NO Change in
configuration since last
poll.
E=1
Change in configuration
since last poll.
(see description of
arguments)