Message Arguments; End Of Packet - Comtech EF Data CDM-700 Installation And Operation Manual

High speed satellite modem
Table of Contents

Advertisement

CDM-700 High Speed Satellite Modem
Remote Control
The '=' code (target to controller) is used in two ways:
First, if the controller has sent a query code to a target – for example, x?, meaning
'what's the Transmit frequency?', the target would respond with TFQ=xxxx.xxxx, where
xxxx.xxxx represents the frequency in question.
Second, if the controller sends an instruction to set a parameter to a particular value, then,
providing the value sent in the argument is valid, the target will acknowledge the
message by replying with TFQ= (with no message arguments).
The ? code (target to controller) is only used as follows:
If the controller sends an instruction to set a parameter to a particular value, then, if the
value sent in the argument is not valid, the target will acknowledge the message by
replying – for example, with TFQ? (with no message arguments). This indicates that
there was an error in the message sent by the controller.
The * code (target to controller) is only used as follows:
If the controller sends an instruction to set a parameter to a particular value, then, if the
value sent in the argument is valid, BUT the modem will not permit that particular
parameter to be changed at that time, the target will acknowledge the message by
replying – for example, with TFQ* (with no message arguments).
The ! code (target to controller) is only used as follows:
If the controller sends an instruction code which the target does not recognize, the target
will acknowledge the message by echoing the invalid instruction, followed by the !
character – for example, with XYZ!
The # code (target to controller) is only used as follows:
If the controller sends a correctly formatted command, BUT the modem is not in remote
mode, it will not allow reconfiguration, and will respond with TFQ#.
The ~ code (target to controller) is only used as follows:
If a message was sent via a local modem to a distant end device or ODU, the message was
transmitted transparently through the local modem. In the event of the distant-end device
not responding, the local modem would generate a response – for example, 0001/RET~,
indicating that it had finished waiting for a response and was now ready for further comms.
11.5.5

Message Arguments

Arguments are not required for all messages. Arguments are ASCII codes for the characters 0 to 9
(ASCII 48 to 57), period (ASCII 46), and comma (ASCII 44).
11.5.6

End Of Packet

Controller to Target: This is the 'Carriage Return' character (ASCII code 13)
Target to Controller: This is the two-character sequence 'Carriage Return', 'Line Feed'. (ASCII
code 13, and code 10.) Both indicate the valid termination of a packet.
11–5
Revision 5
MN/CDM700.IOM

Advertisement

Table of Contents