CDM-700 High Speed Satellite Modem
Front Panel Operation
If M&C Bus Interface
In RS232 Mode the Bus
Address is fixed at 0000
If M&C Bus Interface
RS485 Bus Address: 0001
Edit the RS485 bus address of the modem by selecting the digit to be edited, using the ◄ ►
arrow keys. The value of the digit is then changed using the ▲ ▼ arrow keys. The valid range of
addresses is from 1 to 9999. Press
If Serial Config:
Local M&C Bus Baud Rate:
9600 Baud
Edit the Baud rate of the remote control bus, connected locally to the M&C computer. Values of
1200, 2400, 4800, 9600, 19200, 38400, and 57600 baud are possible. The value is changed using
the ◄ ► arrow keys. Press
Note: The Asynchronous character format is FIXED at 8 data bits, No parity, and 1 stop bit (8-N-
1).
Remote Control:
Ethernet Config: Gateway
Address
Select Gateway, Address, MAC, or SNMP using the ◄ ► arrow keys, then press
If Ethernet Config:
Ethernet IP Gateway:
063.168.001.127 (
The IP Gateway address is the default address that the modem will send all IP responses when the
message originated from a source outside the modems local attached network.
Edit the IP Gateway address by selecting the digit to be edited, using the ◄ ► arrow keys. The
value of the digit is then changed using the ▲ ▼ arrow keys. Press
RS232 is selected:
RS485-2W or RS485-4W is selected, further prompting occurs:
(
E)
.
ENTER
Baudrate is selected:
(
E )
.
ENTER
Ethernet
MAC SNMP
(
Gateway is selected:
6–9
E)
E )
ENTER
Revision 5
MN/CDM700.IOM
.
ENTER
.