ENGINE
3-28
Cam height
®
Intake cams : 33.580 mm (1.3220 in)
Service Limit
Exhaust cams: 33.240 mm (1.3087 in)
CAMSHAFT JOURNAL WEAR
Determine whether or not each journal is worn down to the
limit by measuring the oil clearance with the camshaft installed
in place. Use plastigauge
CD
to read the clearance at the widest
portion, which is specified as follows:
Camshaft-Journal oil clearance (IN & EX)
Service Limit: 0.150 mm (0.0059 in)
09900-22301: Plastigauge (Not available in U.S.A.)
NOTE:
Install each holder to their original positions. (page
3 - 62)
Tighten the camshaft holder bolts evenly and diagonally to the
specified torque.
Tightening torque: 8 - 12 N'm
(0.8 - 1.2 kg-m, 6.0 - 8.5 Ib-ft)
NOTE:
Do not rotate the camshafts with plastigauge inplace.
Remove the camshaft holders, and read the width of com ­
pressed plastigauge with envelope scale. This measurement
should be taken at the widest part.
If the camshaft journal oil clearance measured exceed the limit,
measure the inside diameter of camshaft journal holder and
outside diameter of the camshaft journal. Replace the camshaft
or cylinder head depending on which one exceeds the
specification.
Standard
Journal holder I.D. (IN & EX): 22.012 - 22.025 mm
(0.8666 - 0.8671 in)