Resetting the VCX V7122

The Reset screen enables you to remotely reset the gateway. Before reset you can choose
to save the gateway configuration to flash memory.
To reset the VCX V7122, follow these steps:
1
Click the Reset button on the main menu bar; the Reset screen is displayed.
Figure 53
Reset Screen
2
Select one of the following options:
Burn - (default) the current configuration is burned to flash prior to reset.
Don't Burn - resets the device without burning the current configuration to flash (discards
all modifications to the configuration).
3
Click the Reset button. If the Burn option is selected, all configuration changes are saved
to flash memory. If the Don't Burn option is selected, all configuration changes are
discarded. The device is shut down and re-activated. A message about the waiting
period is displayed. The screen is refreshed.
When Gatekeeper is used, the gateway issues an Unregister request before it is
reset (either from the Embedded Web Server, SNMP or BootP).