3Com VCX V7122 User Manual page 128

Voip sip gateway
Hide thumbs Also See for VCX V7122:
Table of Contents

Advertisement

ini File Field Name
*
Web Parameter Name
ProtocolType_x
[Protocol Type]
TerminationSide
[ISDN Termination Side]
TerminationSide_x
[ISDN Termination Side]
ClockMaster
[Clock Master]
ClockMaster_x
[Clock Master]
TDMBusClockSource
[TDM Bus Clock Source]
TDMBusPSTNAutoClock
Enable
[TDM Bus PSTN Auto Clock]
TDMBusLocalReference
[TDM Bus Local Reference]
LineCode
[Line Code]
LineCode_x
[Line Code]
128
Valid Range and Description
E1_AUSTEL_ISDN
T1_HKT_ISDN
E1_KOR_ISDN
T1_HKT_ISDN
E1_QSIG
T1_QSIG
T1_DMS100_Meridian
Note: The VCX V7122 simultaneously supports different variants of CAS and PRI
protocols on different E1/T1 spans (no more than four simultaneous PRI variants).
Same as "ProtocolType" for specific Trunk ID (x = 0 to 7)
Selects the ISDN termination side. Applicable only to ISDN protocols.
0 = ISDN User Termination Side (TE) (default).
1 = ISDN Network Termination Side (NT).
Note: Select 'User Side' when the PSTN or PBX side is configured as 'Network side',
and vice-versa. If you don't know the VCX V7122 ISDN termination side, choose
'User Side' and see the 'Status & Diagnostics>Channel Status' screen. If the D-
channel alarm is indicated, choose 'Network Side'.
Same as "TerminationSide" for specific Trunk ID (x = 0 to 7).
0 = Recover clock from the E1/T1 line (default).
1 = The clock is generated by the gateway.
See
Appendix E: VCX V7122 Clock Settings
how to configure the gateway's clock settings.
Same as "ClockMaster" for specific Trunk ID (x = 0 to 7)
1 = Generate clock from local source (default).
4 = Recover clock from PSTN line.
See
Appendix E: VCX V7122 Clock Settings
configuring the gateway's clock settings.
0 = Recover the clock from first E1/T1 line (default).
1 = Recover the clock from any connected slave E1/T1 line.
This parameter is relevant only if "TDMBusClockSource = 4".
0 to 7 (default = 0).
Physical Trunk ID from which the gateway recovers its clock. Applicable only if
"TDMBusClockSource = 4" and "PSTNAutoClockEnable = 0".
0 = use B8ZS line code (for T1 trunks only) default.
1 = use AMI line code.
2 = use HDB3 line code (for E1 trunks only).
Use to select B8ZS or AMI for T1 spans, and HDB3 or AMI for E1 spans.
Same as "LineCode" for a specific Trunk ID (x = 0 to 7)
3Com VCX V7122 SIP VoIP Gateway User Manual
= 17
/* Australian Telecom
= 18
/* Hong Kong - HKT
= 19
/* Korean operator
= 20
/* Hong Kong - HKT over T1
= 21
/*Basic call only
= 23
/*Basic call only
= 35
on page
on page
211
for extended details of
211
for detailed information on

Advertisement

Table of Contents
loading

Table of Contents