Traps
Full proprietary trap definitions and trap Varbinds are found in the acBoard MIB and acAlarm
MIB.
The following proprietary traps are supported in the device:
acBoardEvResettingBoard - Sent after the device is reset.
acBoardEvBoardStarted - Sent after the device is successfully restored and initialized
following reset.
acBoardTemperatureAlarm - Sent when a board exceeds its temperature limits.
acBoardConfigurationError - Sent when a device's settings are illegal - the trap contains
a message stating/detailing/explaining the illegality of the setting.
acBoardFatalError - Sent whenever a fatal device error occurs.
acFeatureKeyError - Development pending. Intended to relay Feature Key errors, etc.
acgwAdminStateChange - Sent when Graceful Shutdown commences and ends.
acBoardCallResourcesAlarm - Indicates that no free channels are available.
acBoardControllerFailureAlarm - The Gatekeeper/Proxy is not found or registration
failed. Internal routing table can be used for routing.
acBoardEthernetLinkAlarm - Ethernet link or links are down.
acBoardOverloadAlarm - Overload in one or some of the system's components.
acActiveAlarmTableOverflow - An active alarm could not be placed in the active alarm
table because the table is full.
1
acAtmPortAlarm
- ATM Port Alarm.
acAudioProvisioningAlarm
In addition to the listed traps, the device also supports the following standard traps:
dsx1LineStatusChange.
coldStart.
authenticationFailure.
The following are special notes pertaining to MIBs:
A detailed explanation of each parameter can be viewed in an SNMP browser
in the 'MIB Description' field.
Not all groups in the MIB are functional. See the version release notes.
Certain parameters are non-functional. Their MIB status is marked 'obsolete'.
When a parameter is set to a new value via SNMP, the change may affect device
functionality immediately or may require that the device be soft reset for the
change to take effect. This depends on the parameter type.
The current (updated) device configuration parameters are programmed into the
device provided that the user does not load an ini file to the device after reset.
Loading an ini file after reset overrides the updated parameters.
3Com VCX V7122 SIP VoIP Gateway User Manual
1
- Raised if the Media Server is unable to provision its audio.