The Ini File Example; Basic, Logging, Web, And Radius Parameters - 3Com VCX V7122 User Manual

Voip sip gateway
Hide thumbs Also See for VCX V7122:
Table of Contents

Advertisement

The parameter name is NOT case-sensitive; the parameter value is NOT case-sensitive
except for coder names.
The ini file should be ended with one or more carriage returns.

The ini File Example

Figure 55
shows an example of an ini file for the VoIP gateway.
Figure 55
SIP ini File Example
PCMLawSelect = 1
ProtocolType = 1
TerminationSide = 0
FramingMethod = 0
LineCode = 2
TDMBusClockSource = 4
ClockMaster = 0
;Channel Params
DJBufferMinDelay = 75
RTPRedundancyDepth = 1
IsProxyUsed = 1
ProxyIP = 192.168.122.179
CoderName = g7231,90
;List of serial B-channel numbers
TrunkGroup_1 = 0/1-24,1000
TrunkGroup_2 = 1/1-24,2000
TrunkGroup_3 = 2/1-24,3000
TrunkGroup_4 = 3/1-24,4000
EnableSyslog = 1
SyslogServerIP = 10.2.2.1
CallProgressTonesFilename = 'CPUSA.dat'
;CASFileName = 'E_M_WinkTable.dat'
SaveConfiguration = 1

Basic, Logging, Web, and RADIUS Parameters

In
Table
24, parameters in brackets are the format in the Embedded Web
*
Server
.
3Com VCX V7122 SIP VoIP Gateway User Manual