Hot Replacement - Fujitsu SPARC Enterprise M8000 Service Manual

Oracle
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

19. From the OS, execute the cfgadm -c configure TAPE_Ap_Id command to
configure the tape drive unit to the domain.
# cfgadm -c configure c0::rmt/0
20. From the OS, execute the cfgadm -a command to verify that the status of
CD-RW/DVD-RW drive unit and the tape drive unit has changed from
"unconfigured" to "configured."
# cfgadm -a
Ap_Id
c0::dsk/c0t4d0 CD-ROM connected
c0::rmt/0
21. Close the door on the server, and lock it.
14.3

Hot Replacement

The procedure is as follows.
1. Unlock and open a door of the server. (See
Caution – Before touching a FRU or dummy (filler) unit, see
Precautions" on page 1-9
result in serious damage to operating domains.
2. Stop all connection to the target CD-RW/DVD-RW drive unit.
3. Turn off power to the relevant domain.
From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -d command.
The OS shutdown processing is executed for the relevant domain, and then the power-off
processing is executed.
4. Detach the target CD-RW/DVD-RW drive unit from the port.
From a terminal that is connected to XSCF, log in to XSCF, and execute the cfgdevice -c
detach -p <port no.> command.
14-10
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
Type
Receptacle Occupant
:
tape
connected
:
and be sure to wear the antistatic wrist strap. Failure to do so might
Condition
configured
unknown
configured
unknown
Chapter
5)
Section 1.4, "Antistatic

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents