19. From the OS, execute the cfgadm -c configure TAPE_Ap_Id command to
configure the tape drive unit to the domain.
# cfgadm -c configure c0::rmt/0
20. From the OS, execute the cfgadm -a command to verify that the status of
CD-RW/DVD-RW drive unit and the tape drive unit has changed from
"unconfigured" to "configured."
# cfgadm -a
Ap_Id
c0::dsk/c0t4d0 CD-ROM connected
c0::rmt/0
21. Close the door on the server, and lock it.
14.3
Hot Replacement
The procedure is as follows.
1. Unlock and open a door of the server. (See
Caution – Before touching a FRU or dummy (filler) unit, see
Precautions" on page 1-9
result in serious damage to operating domains.
2. Stop all connection to the target CD-RW/DVD-RW drive unit.
3. Turn off power to the relevant domain.
From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -d command.
The OS shutdown processing is executed for the relevant domain, and then the power-off
processing is executed.
4. Detach the target CD-RW/DVD-RW drive unit from the port.
From a terminal that is connected to XSCF, log in to XSCF, and execute the cfgdevice -c
detach -p <port no.> command.
14-10
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
Type
Receptacle Occupant
:
tape
connected
:
and be sure to wear the antistatic wrist strap. Failure to do so might
Condition
configured
unknown
configured
unknown
Chapter
5)
Section 1.4, "Antistatic