14. Use one of the following methods to start (power on) all domains at once.
The power to all the domains is turned on, and then the power-on self test (POST) is
executed. When ok prompt displayed on the console of relevant domain, POST is
completed.
For details of the power-on operation, see
page
User's Guide.
15. Confirm that the replacement components are normal by using the showhardconf
or showstatus command of XSCF.
Unless "*" is displayed for the replacement FANBP_A or FANBP_B or FANBP_C, it is
operating normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide, the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note – The showstatus command displays information on degraded components.
16. Restore the original mode switch setting on the operator panel.
20-32
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
Press and hold down (for less than four seconds) the POWER switch on the operator
panel.
From a console that is connected to XSCF, execute the poweron -a command of
XSCF.
4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
Section 4.4.2, "Powering the Server On" on