Fujitsu SPARC Enterprise M8000 Service Manual page 319

Oracle
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

7. From the OS, execute the cfgadm -c unconfigure TAPE_Ap_Id command to
unconfigure the tape drive unit from the domain.
# cfgadm -c unconfigure c0::rmt/0
8. From the OS, execute the cfgadm -a command to verify that the status of
CD-RW/DVD-RW drive unit and tape drive unit has changed from "configured" to
"unconfigured."
# cfgadm -a
Ap_Id
Type
c0::dsk/c0t4d0
CD-ROM connected
c0::rmt/0
tape
9. Detach the target CD-RW/DVD-RW drive unit from the port.
From the terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p port no. command.
10. Confirm that the target CD-RW/DVD-RW drive unit is unconfigured from the
domain.
From XSCF, execute cfgdevice -l to confirm that the relevant port is not displayed in
the current connection.
11. Connect the clip of the antistatic wrist strap and of the antistatic mat to the server
grounding port. (See
12. Ensure that the metallic underside of the wrist strap is in direct contact with your
skin.
The wrist strap should be snug around the wrist so that it does not rotate. (See
"Antistatic Precautions" on page
Caution – Before handling FRUs, be sure to connect the clip of the antistatic wrist strap
and of the antistatic mat to the server grounding port, and attach the band of the wrist strap
to one of your wrists. Place the FRUs on the grounded antistatic mat. Failure to take these
antistatic measures might result in serious damage.
Receptacle Occupant
:
unconfigured
connected
unconfigured
:
Section 1.4, "Antistatic Precautions" on page
1-9)
Chapter 14
CD-RW/DVD-RW Drive Unit Replacement
Condition
unknown
unknown
1-9)
Section 1.4,
14-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents