Note – To do maintenance on the IOU or the FAN unit of the M8000 server, push aside the
cables.
Caution – Do not place any cable over a PCI cassette at the front of an IOU in the M8000
server. (Adjust the positioning to divide and bundle the cables.)
Caution – Take care to prevent the cables from blocking the ventilation slits of the M8000
server. (It is recommended to run the cables above the handle of the FAN unit.)
Caution – Keep optical fiber cables as far apart from other cables as possible to prevent the
optical fiber cables from being covered by the other cables.
Caution – Fasten the bundles of cables with the attached hook-and-loop fastener to the
M8000 server, while avoiding the following locations which may affect the system operation:
- The handle or the lever of the AC section
- The handle of the FAN unit
- The handle or the lever of the IOU
- The lever of the PCI cassette
Caution – When bending a cable, keep its bending radius within the permissible bending
radius.
Caution – Take sufficient care not to touch the main line switch when laying cables.
Chapter 4
FRU Replacement Preparation
4-39