Cmu/Iou Add-On As An Upgrade In An Existing Domain - Fujitsu SPARC Enterprise M8000 Service Manual

Oracle
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

XSCF> showhardconf -M
17. Use the showlogs error -v command and the showstatus(8) command, to
confirm that no errors occurred.
XSCF> showlogs error -v
XSCF> showstatus
If you found any errors on the hardware, contact a certified service engineer.
18. Change the mode switch setting on the operator panel from Service to Locked, to put
it back.
19. Configure the following settings for the CMU on which the add-on CPU mounted.
For each setting, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User's Guide, which has the chapter describing "Setting Up XSCF."
20. Set up and confirm the CPU operational mode of the domain.
For details, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User's Guide. In the document, see the chapter of "Setting Up XSCF."
21. Power on the target domain.
XSCF> poweron -d domain_id
22. Confirm that the target domain has been properly started.
XSCF> showlogs power
23. Use the showlogs error -v command and the showstatus(8) command, to
confirm that no errors occurred.
XSCF> showlogs error -v
XSCF> showstatus
If you found any errors on the hardware, contact a certified service engineer.
25.3.6
CMU/IOU Add-on as an Upgrade in an Existing
Domain
1. Update the Oracle Solaris OS to the version of minimum requirements which is
described in the Product Notes of the appropriate XCP version, or apply the
mandatory patches.
25-18
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
XSB settings
LSB settings
Addition of XSB to the domain