Fujitsu SPARC Enterprise M8000 Service Manual page 216

Oracle
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

15. Confirm that the XSCF STANDBY LED (green) on the operator panel remains lit.
If it is blinking, wait until it remains lit.
16. Use one of the following methods to start (power on) all domains at once.
Power to the specified domains is turned on.
When the power to the domain is turned on, the power-on self test (POST) is performed.
When ok prompt displayed on the console of relevant domain, POST is completed. For
details of the power-on operation, see
page
User's Guide.
17. Confirm that the replacement components are normal by using the showhardconf
or showstatus command of XSCF.
Unless "*" is displayed for the replacement IOU (including PCI cards and HDDs), it is
operating normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide, the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note – The showstatus command displays information on degraded components.
18. Restore the original mode switch setting on the operator panel.
Note – When the maintenance work is completed, be sure to confirm the mode switch
setting and return the switch to Locked.
19. Close the door on the server, and lock it.
7-24
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
Press and hold down (for less than four seconds) the POWER switch on the operator
panel.
From the console that is connected to XSCF, execute the poweron -d <domain-id>
command of XSCF for the domain of the replacement target new IOU.
4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
Section 4.4.2, "Powering the Server On" on

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents