The RAID-capable IOUA contains the RAID controller. When the RAID-capable IOUA is
replaced, the disks comprising the RAID boot volume must be reactivated to be able to boot.
This is done from OpenBoot PROM via the OpenBoot PROM command
activate-volume.
1. Confirm that the RAID volume is no longer listed.
{0} ok probe-scsi-all
/pci@0,600000/pci@0/pci@4/scsi@0
MPT Version 1.05, Firmware Version 1.32.06.00
arget 4
Unit 0
SATA device PhyNum 4
2. Select the device and confirm that the RAID volume is reported but inactive.
{0} ok select /pci@0,600000/pci@0/pci@4/scsi@0
{0} ok show-volumes
Volume 0 Target 82 Type IM (Integrated Mirroring)
Optimal Enabled Inactive
2 Members
Disk 1
Primary Online
Target 0
Disk 0
Secondary Online
Target 1
13-26
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
Removable Read Only device
FUJITSU MBD2300RC
FUJITSU MBD2300RC
TEAC
DV-W28S-V
585805824 Blocks, 299 GB
3702
3702
J.0B