Enter a new ES in the Host name text field. For example,
Enter a new ES address in the IP address text field. For example,
Enter a new netmask in the Network mask text field. For example,
Enter a new gateway in the Gateway IP address text field. For example
Enter one or more DNS resolver IP addresses, separated by commas, semicolons, or spaces in the
DNS IP addresses text box. For example:
NOTE
The Sentriant AG ESs host name must be a fully qualified domain name (FQDN). For example, the FQDN should
include the host and the domain name—including the top-level domain.
For example, waldo.mycompany.com. Select names that are short, easy to remember, have no spaces or underscores,
and the first and last character cannot be a dash (-).
NOTE
You cannot change the ES IP address for a single-server installation. You can change the MS IP address for a single-
server installation.

Changing the ES Date and Time

To change the ES date and time:
Home window>>System configuration>>Enforcement clusters & servers>>Select an ES>>Configuration
1 Select a Region from the Region drop-down list in the Date and time area.
2 Select a time zone from the Time zone drop-down list.
3 Click ok.
NOTE
See
"Selecting the Time Zone" on page 61
WARNING!
Manually changing the date/time by a large amount (other than a time zone change) will require a restart of all
servers. Rolling back the clock will have adverse effects on the system.

Modifying the ES SNMP Settings

To change the ES SNMP settings:
Home window>>System configuration>>Enforcement clusters & servers>>Select an ES>>Configuration
Sentriant AG Software Users Guide, Version 5.3
garp.mycompany.com
10.0.16.100,10.0.1.1
for information on changing the time zone settings for the MS.
System Configuration
192.168.153.35
255.255.255.0
192.168.153.2
53