5. SYSTEM MODE
NOTE:
Print conditions:
Preset count: 1, Print speed: 6"/sec. (B-SX4T) or 5"/sec. (B-SX5T), Sensor: No sensor,
Printing mode: Thermal transfer, Media length: 288 mm, Issue mode: Batch printing
Descriptions of the Maintenance Counter
#
(1)
Total media distance
covered
(2)
Media distance covered
(3)
Print distance
(4)
Cut count
(5)
Print head up and down
count
(6)
Ribbon motor driving
time
(7)
Solenoid driving time
(8)
RS-232C hardware error
count
(9)
System error count
(10)
Momentary power failure
count
-------------------------------------------------------------------------------
(44)
LABEL END
(45)
PRE PEEL OFF
(46)
BACK SPEED
(47)
PRTR IP ADDRESS
(48)
GATE IP ADDRESS
(49)
SUBNET MASK
(50)
TTF AREA
(51)
EXT CHR AREA
(52)
BASIC AREA
(53)
PC SAVE AREA
(54)
SOCKET PORT
(55)
BASIC
(56)
BASIC TRACE
(57)
DHCP
(58)
DHCP ID
(59)
ESS ID
(60)
CONNECTION
(61)
CHANNEL
(62)
AUTH
(63)
WEP
(64)
WEP TYPE
(65)
SEND KEY
(66)
WEP KEY #1
(67)
WEP KEY #2
(68)
WEP KEY #3
(69)
WEP KEY #4
Item
Counted when the feed motor drives to feed,
print and issue the media. (Counted also
during ribbon saving operation and back feed.)
See NOTE 6 .
Counted while printing. (back feed is not
counted.) See NOTE 2 .
Counts every cut. See NOTE 3 .
Counts every up and down of the print head
using the solenoid for ribbon save operation.
(Up + down = 1 count) See NOTE 3 .
Counts when the ribbon motor drives to feed,
print and issue the media. (The driving time is
not counted during ribbon saving operation,
but is during back feed.) See NOTE 4 .
Counted during ribbon saving operation.
See NOTE 4 .
Counted when a parity, overrun or framing
error occurs. See NOTE 5 .
Counted when any error occurs.
Counts the number of times the power restores
while the CPU is busy after reset.
[TYPE1]
[OFF]
[STD]
[192.168.010.020]
[000.000.000.000]
[255.255.255.000]
[640KB]
[128KB]
[64KB]
[64KB]
[OFF][08000]
[OFF]
[OFF]
[OFF]
[FFFFFFFFFFFFFFFFFFFF]
[FFFFFFFFFFFF]
[SymbolAP
[
[INFRASTRUCTURE]
[01]
[OPEN SYSTEM]
[OFF]
[40bit]
[1]
[101112131415161718191A1B1C]
[202122232425262728292A2B2C]
[303132333435363738393A3B3C]
[404142434445464748494A4B4C]
Count Condition
5- 6
EO18-33012A
5.3 SELF-DIAGNOSTIC TEST
]
]
Range
0.0 to 3200.0 km
0.0 to 3200.0 km
0.0 to 200.0 km
0 to 1000000 times
0 to 2000000 times
0 to 2000 hours
0 to 1000 hours
0 to 255 times
0 to 15 times
0 to 15 times