Service processor messages
Following is an example of a typical service processor message.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Date/Time: 2002/05/07 15:52:03
DMI Type:
Source: SERVPROC
Error Code: System Complex Powered Up
Error Code:
Error Data:
Error Data:
-
This message indicates that the server was turned on at the recorded time. The
possible service processor error messages are listed in the following table.
Note: Try reseating a suspected component or reconnecting a cable before
Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Service Processor message
1.8V Fault
12V A Bus Fault
12V B Bus Fault
12V C Bus Fault
12V D Bus Fault
12V E Bus Fault
12V F Bus Fault
12V G Bus Fault
12V Planar Fault
2.5V Fault
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
replacing the component.
FRU/action
1. If VRM indicator on light path is on, replace failing VRM 3
or 4.
2. Microprocessor tray assembly.
3. Power supply.
4. Power backplane.
1. Microprocessor tray assembly
2. Power backplane
1. VRM 3 o4r 4
2. Microprocessor tray assembly
3. Power backplane
v Microprocessor tray assembly
1. Hard disk drive
2. SCSI cable
3. SCSI backplane
1. Reseat adapters.
2. I/O board assembly.
1. SCSI backplane
2. I/O board assembly
1. Fan
2. Power backplane
v Power backplane
1. Memory cassette
2. Microprocessor tray assembly
3. Power backplane
Chapter 6. Symptom-to-FRU index
109