Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Service Processor/RXE-100 message
PCI Expansion Unit X Side A or B: PCI planar
area over recommended temperature
PCI Expansion Unit X Side A or B: PCI planar
area over temperature
PCI Expansion Unit X Side A or B: Power
Controller not present
PCI Expansion Unit X Side A or B: Power
Supply X +12V Over Current Fault.
PCI Expansion Unit X Side A or B: Power
Supply X +12V Over Voltage
PCI Expansion Unit X Side A or B: Power
Supply X +12V Under Voltage
PCI Expansion Unit X Side A or B: Power
Supply X +5V Over Current Fault
PCI Expansion Unit X Side A or B: Power
Supply X +5V Over Voltage
PCI Expansion Unit X Side A or B: Power
Supply X +5V Under Voltage
PCI Expansion Unit X Side A or B: Power
Supply X -12V Over Current Fault
PCI Expansion Unit X Side A or B: Power
Supply X -12V Over Voltage
PCI Expansion Unit X Side A or B: Power
Supply X -12V Under Voltage
PCI Expansion Unit X Side A or B: Power
Supply X AC Power Removed
PCI Expansion Unit X Side A or B: Power
Supply X Aux +5V Over Voltage
PCI Expansion Unit X Side A or B: Power
Supply X Fan Failure
PCI Expansion Unit X Side A or B: Power
Supply X Fault
PCI Expansion Unit X Side A or B: Power
Supply X Over Temperature
120
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Check all fans and remove any obstacles from the path of
airflow in RXE-100.
2. Verify room temperature is within recommended range.
1. Check all fans and remove any obstacles from the path of
airflow in RXE-100.
2. Verify room temperature is within recommended range.
1. Reseat power backplane.
2. Power backplane.
3. DMC card.
v Power supply
v Power supply
1. Check adapters for shorts.
2. Verify pins on adapters are not damaged.
3. Power supply.
v Power supply
v Power supply
1. Check adapters for shorts.
2. Verify pins on adapters are not damaged.
3. Power supply.
v Power supply
v Power supply
1. Check adapters for shorts.
2. Verify pins on adapters are not damaged.
3. Power supply.
1.
Insert the ac cord into the referenced power supply in the
RXE-100
2.
Replace power supply X.
v Replace power supplies, one at a time.
v Reseat/replace power supply.
1. Verify ac power is functioning correct.y.
2. Power supply.
1.
Verify proper operation of the fan inside the power
RXE-100 power supply
2.
Replace power supply X.