IBM 8862 - Eserver xSeries 365 Maintenance And Troubleshooting Manual page 58

Hardware maintenance manual and troubleshooting guide
Hide thumbs Also See for 8862 - Eserver xSeries 365:
Table of Contents

Advertisement

48
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
c. Pull out the microprocessor tray ( 3) ).
Note: The new microprocessor comes in a kit with a VRM and a heat sink.
The VRM is used only with microprocessors 3 and 4.
Captive screws
Microprocessor 3
Microprocessor 3
VRM
Microprocessor-tray
levers
7. Remove the microprocessor baffle from the empty microprocessor socket and
store the microprocessor baffle for future use.
8. Remove the protective cover, tape, or label from the surface of the
microprocessor socket, if any is present.
9. Lift the microprocessor-release lever to the open position (135°).
Heat sink 3
Microprocessor
baffle
Lever closed
Lever
fully
open
Lever closed
Lever
fully
open

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 365 8862Xseries 365 8861

Table of Contents