Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Service Processor message
Fan X Failure (X of 1-6 = individual fans 1
through 6; X of 7=power supply 1; X of 8=power
supply 2.)
Fan X not detected (X of 1-6 = individual fans
1 through 6; X of 7=power supply 1; X of
8=power supply 2.)
Fan X Outside Recommended Speed (X of
1-6 = individual fans 1 through 6; X of 7=power
supply 1; X of 8=power supply 2.)
Front Panel is not plugged in
Hard Drive X Fault
Hard drive X removal detected
Hostname set to <value> by user <USERID>
Hot plug card is not plugged in
Integrated Systems Management Processor
encountered failures upon starting
Internal Error CPU X Fault
Internal SCSI cable is not plugged in
Invalid CPU configuration
Invalid Fan configuration
FRU/action
1. Verify no obstacles are blocking or inserted into the fan or
power supply.
2. Check the physical connection and verify fan or power supply
is properly seated.
3. Replace component X:
a. Where X = a number from 1 through 6, replace fan X.
b. Where X = 7 or 8, replace power supply X.
1. Verify no obstacles are blocking or inserted into the fan or
power supply.
2.
Check the physical connection and verify fan or power supply
is properly seated.
3. Replace component X:
a. Where X = a number from 1 through 6, replace fan X.
b. Where X = 7 or 8, replace power supply X.
1. Verify no obstacles are blocking or inserted into the fan or
power supply.
2.
Check the physical connection and verify fan or power supply
is properly seated.
3. Replace component X:
a. Where X = a number from 1 through 6, replace fan X.
b. Where X = 7 or 8, replace power supply X.
1. Verify operator panel cables are properly connected (verify
LED activity).
2. Replace operator information panel.
1. Run diagnostics.
2. Hard disk drive.
3. ServeRAID adapter.
4. SCSI backplane.
v Re-insert hard disk drive X and restart server.
v Information only
1. Verify PCI cabling.
2. Failing hot plug cable/card.
1. Remove ac power from the server and restart the server
2. Run diagnostics.
v Microprocessor X
1. Verify SCSI cables are properly connected.
2. SCSI backplane.
v Verify that microprocessors have been installed in the
correct order (see "Installing a microprocessor" on page
44).
v Replace any missing or failed fans.
Chapter 6. Symptom-to-FRU index