Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom
01298001 (No update data for processor 1)
01298002 (No update data for processor 2)
01298004 (No update data for processor 3)
01298005 (No update data for processor 4)
01298101 (Bad update data for processor 1)
01298102 (Bad update data for processor 2)
01298103 (Bad update data for processor 3)
01298104 (Bad update data for processor 4)
0I298200 (Processor speed mismatch)
I9990301 (Fixed disk sector error)
I9990305 (Operating system not found)
I9990650 (AC power has been restored)
92
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 1.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 2.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 3.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 4.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 1.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 2.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 3.
1. Ensure all microprocessors are the same cache size.
2. Reflash BIOS code.
3. Microprocessor 4.
v Ensure all microprocessors are the same cache size.
1. Hard disk drive
2. SCSI backplane
3. Cable
4. I/O board
1. Verify a bootable operating system is installed.
2. Run diagnostic programs.
3. Hard disk drive.
4. SCSI backplane.
5. Cable.
6. I/O board.
1. Check cables.
2. Check for interruption of power supply.
3. Power cable.
4. Power backplane.