Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
No beep symptom
System will not power-up
(Power supply ac LED is on)
POST error codes
In the following error codes, X can be any number or letter.
Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom
062 (Three consecutive boot failures using the
default configuration.)
101, 102 (Tick timer internal interrupt, internal
timer channel 2)
106 (Diskette controller failure)
114 (Adapter read-only memory (ROM) error)
151 (Real time clock error)
161 (Real time clock battery error)
162 (Device Configuration Error)
Note: Be sure to load the default settings and
any additional desired settings; then, save the
configuration
163 (Real-Time Clock error)
175 (Hardware error)
177, 178 (Security hardware error)
184 (Power-on password corrupted)
186 (Security hardware control logic failed)
88
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
v See "Power LED errors" on page 130.
FRU/action
1. Flash system to latest level.
2. I/O board.
v I/O board
v I/O board
1. Remove adapters and reinstall one at a time; replace failing
adapter.
2. I/O board.
1. Battery
2. I/O board
1. Battery
2. I/O board
1. Run Configuration/Setup
2. Battery
3. Failing device
4. I/O board
1. Run Configuration/Setup.
2. Battery.
3. I/O board.
1. I/O board
2. Service processor
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.
1. Run Configuration/Setup.
2. Battery.
3. I/O board.
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.