Power-supply structure

This section contains information about removing and replacing the power-supply
structure.
Note:
Complete the following steps to remove the power-supply structure:
1. Turn off the server and all peripheral devices; then, disconnect all power cords
2. Remove the top cover (see "Removing the cover and bezel" on page 32).
3. Remove the fans (see "Replacing a hot-swap fan" on page 55).
4. Remove the memory cassette (see "Installing a microprocessor" on page 44).
5. Remove the power supplies (see "Installing a hot-swap power supply" on page
6. Pull the two blue latches ( 1 ) on the power-supply structure toward the front of
7. Grasp the handle in the middle of the structure and rotate the back of the
8. Slide the structure toward the rear of the server ( 3 ), disengaging the tabs on
78
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
a. The tabs on the bottom of the insulators sit in the holes in the bottom of the
metal section of the bracket.
b. The tabs on the top of the insulators engage the plastic retainer section of
the bracket.
v Read "Installation guidelines" on page 29.
v Read "Safety information" on page 147.
v Read "Handling static-sensitive devices" on page 30.
and external cables.
51).
the server; the structure will disengage from the chassis.
structure up ( 2 ), allowing the structure to pivot at the end closest to the front
of the chassis.
the structure from the slots in the server ( 4 ).
Handle