IBM 8862 - Eserver xSeries 365 Maintenance And Troubleshooting Manual page 118

Hardware maintenance manual and troubleshooting guide
Hide thumbs Also See for 8862 - Eserver xSeries 365:
Table of Contents

Advertisement

Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
SMI message code
1513 (MCA: Excessive Recoverable
Errors)
1514 (Rebuilding PCI BUS Map)
1515 (Excessive single-bit Errors
Detected)
1516 (WARNING: Memory Socket ECC
Failure)
151802 (Error configuring DIMMS,
mismatch detected)
151803 (Memory ProteXion Event
Detected)
151805 (Error Reading Port Door Status)
151806 (Memory door opened/closed
while memory copy in progress)
108
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
Suggested action
1. Run system diagnostic programs.
2. Microprocessor x (where x = indicated microprocessor).
3. VRM.
4. Microprocessor tray assembly.
v Information only.
Run memory diagnostic programs; then, replace indicated
memory DIMM.
Run memory diagnostic programs; then, replace indicated
memory DIMM.
1. Remove any recently added memory DIMMs.
2. Reseat DIMMs.
3. Replace DIMMs one at a time to isolate failure.
Information only; run memory/system diagnostic programs when
multiple entries accumulate.
1. Run memory door diagnostic programs.
2. Memory cassette, if indicated.
v Information only.