Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Light path LED
LOG (non-optimal condition)
OVER SPEC (power supplies are
being overdriven)

Diagnostic error codes

Note: In the following error codes, if xxx is 000, 195, or 197, do not replace a FRU.
Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom
001-198-000 (Test Aborted)
001-250-00x (Test Failed)
x of 0 = ECC logic on I/O board; x of 1 =
ECC logic on memory board
001-292-000 (Core system: failed/CMOS
checksum failed)
001-xxx-000 (Failed core tests)
001-xxx-001 (Failed core tests)
005-xxx-000 (Failed Video test)
011-xxx-000 (Failed COM1 Serial Port
test)
015-xxx-001 (Failed USB test)
015-xxx-015 (Failed USB external
loopback test)
015-xxx-198 (Remote Supervisor Adapter
II installed) or (USB device connected
during USB test)
FRU/action
1. See System Error log.
2. See Service Processor log.
1. Power supply
2. Power backplane
The description for these error codes are:
000
The server passed the test.
195
The Esc key was pressed to end the test.
197
This is a warning error and might not indicate a hardware failure.
For all error codes, replace the FRU or follow the action indicated.
FRU/action
1. Check error log for messages.
2. Run Quick Memory Test All Banks.
3. Reload server BIOS code and rerun test.
1. Check error log for messages.
2. Run Quick Memory Test All Banks.
3. Rerun ECC test.
4. Memory cassette.
5. I/O board.
Load BIOS defaults and rerun test.
v I/O board
v I/O board
v I/O board
v I/O board
v I/O board
v I/O board
1. If Remote Supervisor Adapter II is installed as an option,
remove it and rerun test.
Note: If Remote Supervisor Adapter II is present as a standard
installation, do not remove it; the test cannot be run.
2. Remove USB devices and rerun test.
3. I/O board.
Chapter 6. Symptom-to-FRU index
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 365 8862Xseries 365 8861

Table of Contents