Alpine 3800 Series Switch Specifications - Extreme Networks Summit 300-24 Hardware Installation Manual

Summit 200 e, 300 e, 400 e, i series
Hide thumbs Also See for Summit 300-24:
Table of Contents

Advertisement

Table 80: Summit "i" series model-specific specifications (continued)
Summit7i
AC Line Frequency
Nominal Operating Voltage
Current Rating
Summit48i
AC Line Frequency
Nominal Operating Voltage
Current Rating
Summit48si
AC Line Frequency
Nominal Operating Voltage
Current Rating
DC Power Supplies
Summit48si
DC power cable size
Input power
Max input amps
Switch Power-Off
Temperature power-off

Alpine 3800 Series Switch Specifications

The Alpine 3800 series switches include the Alpine 3808, Alpine 3804, and Alpine 3802 switches.
Table 81 lists specifications common to all Alpine models; Table 82 lists model-specific specifications.
Table 81: Alpine 3800 common specifications
Safety
Certifications and Standards
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
50 Hz to 60 Hz
90 VAC to 264 VAC
100-120 VAC 10 A
200-240 VAC 5 A
50 Hz to 60 Hz
85 VAC to 250 VAC
100-120 VAC 3 A
200-240 VAC 1.5 A
50 Hz to 60 Hz, auto ranging
100 VAC to 240 VAC
100-120 VAC 3 A
200-240 VAC 1.5 A
2
14 AWG (2mm
), high-strand count copper wire
-40 to -60 V DC
4.2 A
Summit1i, Summit5i, Summit48i
Power-One supplies: 75° to 80° C (167° to 176° F)
Summit 7i
Martek supplies: 75° C (167° F)
UL 1950 3rd Edition, listed
Alpine 3802:UL 60950 3rd Edition, listed
cUL listed to CAN/CSA-C22.2 No. 60950-00
EN60950:1992 A1-A4, A11:1996 plus deviations
IEC950CB, IEC 60950:1991 A1-A4:1996 2nd Edition
Alpine 3802: IEC 60950:1999 3rd Edition
Low Voltage Directive (LVD)
AS/NZS 3260
S-Mark (Argentina)
EN60825-1 + A11:1996
FCC CFR 21, CDRH