Connecting The Eps-Ld To The Switch - Extreme Networks Summit 300-24 Hardware Installation Manual

Summit 200 e, 300 e, 400 e, i series
Hide thumbs Also See for Summit 300-24:
Table of Contents

Advertisement

To rack mount each EPS-LD unit:
1 Place the EPS-LD unit upright on a hard flat surface, with the side you want to face to the front of
the switch toward you.
2 Remove the mounting bracket kit (including screws) from the packaging.
3 Locate a mounting bracket over the mounting holes on one side of the unit.
4 Insert the screws as shown in Figure 58, and fully tighten the screws with a #1 Phillips screwdriver.
Figure 58: Fitting the mounting bracket
5 Repeat steps 3 and 4 for the other side of the EPS-LD unit.
6 Insert the EPS-LD unit into a 19-inch rack.
NOTE
Mount the EPS-LD so that the output connectors are on the same side as the external connector on
the connecting switch. If you mount the EPS-LD with the connectors facing in the opposite direction
as the Extreme switch connector, leave at least 1 U between the switch and the EPS-LD through
which to slide the cables. Do not route the cables around the equipment rack.
7 Insert the screws into the rack and the mounting bracket on both sides of the unit and fully tighten
with a suitable screwdriver.

Connecting the EPS-LD to the Switch

CAUTION
Do not attach the AC power cord to the EPS-LD unit until the unit is properly grounded at the electrical
outlet and the redundant power supply cable is connected.
One end of the EPS-LD cable has a keyed connector to ensure correct alignment of the connector
(Figure 59). The key is a plastic tab on the cable connector housing that fits into the EPS-LD unit.
Figure 59: EPS-LD cable with key
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
Installing or Removing an External Power Supply 45019 (EPS-LD)
Collin's
ES4K026
XM_054
Collin's
ES4K027
XM_055
119