Removing An Eps-Ld Unit - Extreme Networks Summit 300-24 Hardware Installation Manual

Summit 200 e, 300 e, 400 e, i series
Hide thumbs Also See for Summit 300-24:
Table of Contents

Advertisement

Installing and Connecting Alpine 3800 Series Switch Power Supplies
Figure 96: Connecting an EPS-LD unit to a FM32Pi module
EPS-LD
To AC
FM-32Pi
3 Connect the AC input power cable to the AC connector on the EPS-LD unit.
CAUTION
The EPS-LD unit does not have a switch for turning the unit on and off. You disconnect power to the
EPS-LD unit by removing the plug from the electrical outlet. Make sure this connection is easily
accessible.
4 Connect the other end of the AC cable to the electrical outlet.
Make sure the electrical outlet is properly grounded.
NOTE
Consider all the equipment connected to the power supply circuit to ensure that the circuit is not
overloaded. Use proper overcurrent protection, such as a circuit breaker, to prevent overcurrent
conditions.
The Power LED on the front of the EPS-LD unit turns solid green to indicate that it is ready. Table 33
shows the possible LED status for the power supply.
Table 33: LED status for EPS-LD Power LED
Power LED
Indicates
Green, solid
The external power supply is operating normally.
Off
The external power supply is not connected.

Removing an EPS-LD Unit

To remove an EPS-LD unit:
1 Disconnect the AC power by removing the plug from the wall.
2 Disconnect the AC power cord from the EPS-LD unit.
3 Remove the cable that connects to the Extreme switch from the EPS-LD unit.
4 Loosen the thumbscrews on the front of the EPS-LD mounting racks.
5 Slide EPS-LD unit out of rack.
174
Keyed end of
redundant power cable
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
Slot for key
Redundant
power cable