Table 74: Summit 300-48 internal power supply environmental and safety specifications (continued)
Electromagnetic Interference/ Compatibility (EMI/EMC)
Certifications and Standards
Environmental Operating Conditions
Operating Temperature
Storage Temperature
Operating Humidity
Operational Shock
Standards
Table 75 lists the specifications for the EPS-160 external power supply for the Summit 400-48t and
Summit 400-24t switches.
Table 75: EPS-160 AC Power Supply Specifications
AC Input Specifications
Input Voltage
Current Rating
Maximum Inrush
Current
Output Specifications
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
North America EMC for ITE
• FCC CFR 47 part 15 Class A
• ICES-003 Class A
European EMC standards for ITE
• EN 55022:1998 Class A
• EN 55024:1998 Class A (includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11)
• EN 61000-3-2,3 (Harmonics & Flicker)
• ETSI EN 300 386:2001 (EMC Telecommunications)
• 89/336/EEC EMC Directive
International EMC Certifications
• CISPR 22:1997 Class A
• CISPR 24:1997 Class A
• VCCI Class A (Japan)
• AS/NZS 3548 (Australia)
• CNS 13438:1997 Class A (BSMI-Taiwan)
• MIC Mark (Korea)
0° to 40° C (32° to 104° F)
-40° to 70° C (-40° to 158° F)
10% to 95% relative humidity, noncondensing
30 m/s2 (3g)
EN/ETSI 300 019-2-1 v2.1.2 – Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 – Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 – Class 3.1e Operational
EN/ETSI 300 753 (1997-10) – Acoustic Noise
ASTM D5276 Drop Packaged
ASTM D3580 Random Vibration Packaged 1.5G
100 VAC to 240 VAC, 50 Hz to 60 Hz
4A at 100 VAC, 2A at 240 VAC
30A at 100 VAC, 50A at 50 VAC
+12V DC, maximum output current 13A
+5V DC, maximum output current 1.5A