Extreme Networks Summit 300-24 Hardware Installation Manual page 173

Summit 200 e, 300 e, 400 e, i series
Hide thumbs Also See for Summit 300-24:
Table of Contents

Advertisement

Figure 94: EPS-LD connecting cable for connecting to PoE modules
3
1
4
2
NOTE
Only trained service personnel should install or remove the Extreme EPS-LD unit, in accordance with
the installation instructions. Before servicing this system, please read the safety information provided in
Appendix A. Not following these precautions can result in equipment damage or shock.
CAUTION
Do not attach the AC power cord to the EPS-LD unit until the unit is properly grounded at the electrical
outlet and the redundant power supply cable is connected.
One end of the EPS-LD cable has a keyed connector to ensure correct alignment of the connector
(Figure 95). The key is a plastic tab on the cable connector housing that fits into the EPS-LD unit.
Figure 95: EPS-LD cable with key
To connect the EPS-LD cable:
1 Connect the keyed end of the EPS-LD cable to the power supply unit(s).
See Figure 96 to locate the connectors on the EPS-LD unit and on the FM32Pi module.
NOTE
The cable length is 1.5 meters.
2 Connect the other end to the circular power connector on the front panel of the FM-32Pi.
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
Installing the Alpine 3800 Series Switch External Power Supply
Collin's
ES4K027
XM_055
14
7
8
1
EPSLD01
173