Connecting Redundant Power Cables for the EPS-C2
Chassis
4. Push the power supply in until the latch snaps into place.
Figure 209: Installing a 750 W AC Power Supply in an EPS-C2 Chassis
Repeat the procedure to install each additional power supply.

Connecting Redundant Power Cables for the EPS-C2 Chassis

The EPS-C2 chassis can use up to five 2x7-pin redundant power connectors, shown in
connect the power supply to ExtremeSwitching X440-G2 and X620 switches.
Figure 210: EPS-C2 2x7 Pin Redundant Power Cable with Connector Key Tab
268 ExtremeSwitching Hardware Installation Guide
Caution
Do not slam the power supply into the chassis.
Note
If power supplies are not installed in all three slots, be sure to install a cover over each
unoccupied slot. Unoccupied slots must always be covered to maintain proper system
ventilation and EMI levels.
Installing External Power Supplies