Overview of Smart Functions

6-1

Overview of Smart Functions

6-2

Registration Table

6-2-1

Making a Registration Table

Precaution for
Correct Usage
54
This section gives an overview of the smart functions of the CompoNet Smart-
Slice system.
Function
Registration
The Registration Table contains information
Table
on the SmartSlice I/O Units in the Smart-
Slice I/O Terminal.
Backup Function You can read the parameter settings from all
SmartSlice I/O Units in the SmartSlice I/O
Terminal and save them.
Automatic
You can automatically restore the parameter
Restore Function
settings that you backed up in the Compo-
Net Communications Unit.
Replacing Units
You can replace a SmartSlice I/O Unit with-
Online
out turning OFF the power supply.
Automatic Baud
The CompoNet Communications Unit auto-
Rate Recogni-
matically uses the same baud rate as the
tion
CompoNet Master Unit.
Software Setting
You can set Dummy Units (SmartSlice I/O
of I/O Allocations
Units that are not installed at this time) in a
Software Setting Table. The settings include
the node address and I/O configuration
information.
Unit Conduction
The system calculates and records the time
Time Monitor
that the internal power supply in the Unit is
ON in increments of 0.1-hour.
Unit Comments
You can set a comment (for example, a
name) for each SmartSlice I/O Unit.
Network Com-
The system records the last four errors in
munications
communications with the CompoNet net-
Error History
work.
Monitor
I/O Communica-
The system records the last 64 errors in
tions Error His-
communications between the CompoNet
tory Monitor
Communications Unit and the SmartSlice
I/O Units.
Last Mainte-
You can record the last date you did mainte-
nance Date
nance.
You can use the DIP switch on the CompoNet Communications Unit to record
the connected SmartSlice I/O Units in a table. The table tells the sequence
and I/O capacity of each SmartSlice I/O Unit.
When the power is subsequently turned ON, the CompoNet Communications
Unit automatically compares the information in the Registration Table with the
connected SmartSlice I/O Units.
• Before making the Registration Table, make sure that all SmartSlice I/O Units
are participating in communications. The TS indicators must be lit in green.
• Before making the Registration Table, make sure that pin 2 (I/O) on the DIP
switch is OFF (Automatic I/O Allocation Mode). You cannot make the Registra-
tion Table if pin 2 is ON (Software I/O Allocation Mode).
Overview
Section 6-1
Method
DIP switch
DIP switch
DIP switch
---
---
DIP switch
(You use the CX-
Integrator to make,
download, and clear
the Software Set-
ting Table.)
CX-Integrator or
explicit messages
CX-Integrator or
explicit messages
CX-Integrator or
explicit messages
CX-Integrator or
explicit messages
CX-Integrator or
explicit messages