Page 1
RFID System V680 Series Next-Generation RFID System Conforming to ISO/IEC 18000-3 (ISO/IEC 15693). New ID Sensor Units for CJ1/CS1 PLCs and New M12 Antenna. Visualize data transmission on production lines. Managing process instructions Managing manufacturing process and histories for engine...
Page 2
Kong, Taiwan, and Korea. Contact your OMRON sales representative for details on use in other countries. Note: The requirements of radio wave regulations have been met in the countries listed above for combinations of a V680-HA63A or V680-HA63B Amplifier and a V680-HS52, V680-HS63, or V680-HS65 Antenna (application pending in Mexico). The V680-CH and V680-H01 Antennas and combinations of a V680-HA63A or V680-HA63B Amplifier and a V680-HS51 Antenna meet the requirements of radio wave regulations in Japan, Europe, the U.S.A., and Canada.
Page 3
Contributes to higher efficiency for on-site startup and maintenance. Seven maintenance modes make it easy to diagnose the optimal usage conditions for the V680 RFID System. Startup is also easier because the system can be checked without having to use a personal computer or other host device.
Page 4
Data is transmitted repeatedly to moving ID Tags, and the number of successful communications and speed level are displayed in levels ranging from 01 to 99. (No data is actually written to the ID Tags during the write part of the Speed Level Measurement Mode.) Controller...
Page 5
Seven maintenance modes make it easy to diagnose the communications conditions from the front panel of the Controller or Amplifier Unit. The data can also be output from the USB port of the Controller to a personal computer or other monitoring device.
2. For details, refer to the following User’s Manuals (Cat. No. Z248, Z249, Z262, and Z274). 3. The maximum total cable length is 62.5 m. It is achieved by connecting an Antenna with a 12.5-m cable, an Amplifier with a 10-m cable, and 20-m Amplifier Unit Special Extension Cables.
Page 7
Connect V680 Read/Write Antennas and Amplifier Units to a V680-series Controller, and read or write data from or to V680-series ID Tags. Transmission is also possible with ID Tags other than those of the V680 Series as long as they comply with ISO/IEC 18000-3 (ISO/IEC 15693).
Size Cable length Model 250 × 200 × 35 mm Square 0.5 m (See note.) V680-H01 Note: Use an Antenna Cable to connect the Read/Write Antenna to the Controller. The maximum cable length is 30.5 m. V680 Series RFID System...
For 2-/8-/32-Kbyte memory V680-HA63B 5M 10 m V680-HA63B 10M Note: The maximum extendable cable length is 50 m (including the Amplifier Unit cable). The maximum number of V700-A43/-A44 Amplifier Unit Special Extension Cables that can be connected is two. Controller Type No.
Page 10
V700-A40-W 20M 30 m V700-A40-W 30M Note: The maximum cable length is 30.5 m. If extending the cable length, connect only one additional cable. (Do not connect more than two cables together.) RS-232C Communications Connector ID Map Manager (for Windows)
Metallic compatibility Note 1. Refer to the User's Manual (Cat. No. Z262) for data backup time for temperatures of 85 ° C or higher. If the V680 has been stored at 125 ° C or higher, write the data again even if the data does not need to be changed.
Page 12
Approx. 7 g Metallic compatibility Note 1. Refer to the User's Manual (Cat. No. Z248) for data backup time for temperatures of 55 ° C or higher. 2. The total Read or Write communication frequency is called the access frequency.
Page 13
Approx. 850 g (with 12.5-m cable) Approx. 55 g (with 2-m cable) Note 1. The degree of protection for the Connector is IP67/IP65. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
Page 14
0.5 m (See note 1.) Note 1. Use an Antenna Cable to connect the Read/Write Antenna to the Controller. The maximum cable length is 30.5 m. If extending the cable length, connect only one additional cable. (Do not connect more than two cables together.) 2.
Page 15
■ USB Port The USB port is used for a simple connection with a personal computer using a USB cable. The port complies with USB 1.1, and the USB cable uses a series A or series mini-B connector. A USB port driver must be separately provided. Consult with your OMRON representative for details.
Page 16
Mounted in panel (IP30) Vibration resistance 10 to 57 Hz variable vibration, 0.075-mm double amplitude and 57 to 150 Hz variable vibration at 9.8 m/s acceleration, with 10 sweeps in X, Y, and Z directions for 8 minutes each Shock resistance...
Insulation resistance 100 M Ω min. (at 500 VDC) between input terminals and output terminals Dielectric strength 1,500 V for 1 minute between input terminals and output terminals with a current leakage of 5 mA max. Weight Approx. 85 g...
Page 18
Handheld Terminal Accessories Name Appearance Size Psion Teklogix model number OMRON model number High-capacity Battery 55 × 35 × 18 mm WA3006 V680-A-WA3006 Charger Adapter: 48 × 70 × 27 mm CA1053 V680-A-CA1053 (standard model) Cable: 1,800 mm Charger Charger: 168 × 185 × 110 mm...
Page 19
210 × 90 × 42 mm Weight 390 g (excluding battery) Standards CE, UL 60950-1, CSA C22.2 No. 60950-1 CCC, and RoHS (AC Adapter for the charger) Note: The Easy Access demonstration software is preinstalled on the V680 and V600. Charger (Standard Model) Model...
Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not need to be used, however, if the mounting brackets on the Antenna are metal plates and their dimensions are larger than the dimensions of the Antenna (100 ×...
Page 21
Recommended combination Function Transmission distance ID Tag and Read/Write Antenna mounting (unit: mm) conditions ID Tag Read/Write Antenna V680-D1KP66T V680-HS52 Read 0 to 17.0 mm V680-D1KP66T (axial deviation ± 2) distance (See note 2.) V680-HS52 Write 0 to 17.0 mm (axial deviation ±...
Page 22
Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not need to be used, however, if the mounting brackets on the Antenna are metal plates and their dimensions are larger than the dimensions of the Antenna (100 ×...
Page 23
ID Tag (2-kbyte Memory) Transmission Recommended combination Function Transmission distance ID Tag and Read/Write Antenna mounting (unit: mm) conditions ID Tag Read/Write Antenna V680-D2KF52M V680-HS52 Read 0 to 8.0 mm V680-D2KF52M (axial deviation ± 2) distance V680-HS52 Write 0 to 8.0 mm (axial deviation ±...
Page 24
Note: When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not need to be used, however, if the mounting brackets on the Antenna are metal plates and their dimensions are larger than the dimensions of the Antenna (100 ×...
1-kbyte Memory ID Tag The values given for communications ranges are reference values. Refer to pages 20 to 22 for communications distance specifications. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. Test operation completely when installing a system.
Page 26
V680-HS51 (embedded in metallic material) & V680-HS51 (embedded in metallic material) & V680-D1KP52MT V680-D1KP52MT (embedded in metallic surface: steel) Read Write Read Write −50 −40 −30 −20 −10 −50 −40 −30 −20 −10 V680-HS63 (mounted on non-metallic material) & V680-HS52 (embedded in non-metallic material) &...
Page 27
V680-HS65 (mounted on metallic material) & V680-HS52 (embedded in non-metallic material) & V680-D1KP66T-SP V680-D1KP66MT (flush-mounted on metallic surface: steel) Read Write Read Write −50 −40 −30 −20 −10 −100 −80 −60 −40 −20 V680-HS63 (mounted on non-metallic material) & V680-HS65 (mounted on metallic material) &...
Page 28
2-kbyte Memory ID Tag The values given for communications ranges are reference values. Refer to pages 23 to 24 for communications distance specifications. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. Test operation completely when installing a system.
Page 30
8-/32-Kbyte Memory ID Tag The values given for communications ranges are reference values. Refer to page 24 for communications distance specifications. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. Test operation completely when installing a system.
8-/32-Kbyte Memory ID Tag V680-D8KF@@, V680-D32KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B Amplifier Unit) ● Transmission speed: Normal mode ● Transmission speed: High-speed mode...
Page 32
1,000 1,647 Note 1. These are the TAT values for a baud rate of 115,200 bps. For information on the TAT for baud rates other than 115,200 bps, refer to the User's Manual. 2. The V680-H01 Read/Write Antenna cannot be used in high-speed mode.
Page 33
2,000 2,031 Note 1. These are the TAT values for a baud rate of 115,200 bps. For information on the TAT for baud rates other than 115,200 bps, refer to the User's Manual. 2. When multi-access or FIFO is selected as the transmission option, the transmission time will be the same as in normal mode even when the transmission speed is set to high-speed mode.
Page 34
2,000 2,030 Note 1. These are the TAT values for a baud rate of 115,200 bps. For information on the TAT for baud rates other than 115,200 bps, refer to the User's Manual. 2. When multi-access or FIFO is selected as the transmission option, the transmission time will be the same as in normal mode even when the transmission speed is set to high-speed mode.
4. Be sure to use wiring crimp terminals of the specified size. Store the product at a location where: 5. If any cable has a locking mechanism, be sure to check that it has • It is not exposed to corrosive gases, dust, metal chips, or salt.
Page 36
Dimensions Note: All units are in millimeters unless otherwise indicated. ID Tag V680-D1KP52MT/-D2KF52M V680-D1KP66T/-D1KP66MT Mounting Hole Dimensions R0.2 dia. 4-R4 −0.1 4-R3 ±0.2 Two, M3 Two, ±0.2 ±0.2 3.5 dia. −0.1 ±0.2 Two, ±0.1 Case material PPS resin 6 dia.
Page 37
Insulated cover 14.5 dia. ±0.1 16.5 dia. 16.5 dia. Connector 5.5-dia. coaxial cable Ferrite core Operation indicator Mounting Hole Dimensions Two, M4 or 4.5 dia. Center of coil Case material ABS resin Filling Epoxy resin Cable V680-HS63-R Insulated cover ±0.1 14.5 dia.
Page 39
1900 160.5 10.5 Case material ABS resin 3.8-dia. vinyl-insulated round cable Nameplate material PET resin Antenna Standard length: 0.8 or 1.9 m Ferrite core V680-CH1D Activate switch Operation indicator Reset button 25.5 3.8-dia. vinyl-insulated round cable Standard length: 2.5 m 2500 ±60...
Page 40
Epoxy resin V680-D1KP58HT Attachments V680-A80 Mounting Hole Dimensions 12 dia. 20 dia. 3.2 dia. 11.5 V680-H01 Special Cables Note: The model numbers for each length (L1) are as follows: V700-A40-W 2M 41.8 ±100 (See note.) Model Length L1 V700-A40-W 5M...
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: •...