COMSPHERE 6800 Series Nework Management System

Defining a 724/735 Profile

If you have 724/735 multiplexers attached to the NETWORKER, you must define a profile
(channel port) for each pair (master and slave) of the multiplexers. To define a profile for a
724/735 channel port, use the procedures described in the Defining a Profile for a Channel Port
section. The parameters for the 724/735 profile in Step 6 should match those shown below:
Once you have defined a profile for the 724/735 port, you must assign that profile number to a
channel. To do this, use the procedures described previously in this chapter in Assigning a Profile
to a Channel Port.
After you assign the 724/735 profile number to a channel, you must define a separate channel
group for the 724/735 channel port. The procedures for defining the channel group are the same as
those described in Defining a Channel Group for a Terminal or PC with one exception: in Step 3
instead of selecting the Local Group, select the Datagram Group (Option 5). Selecting Option 5
causes the Datagram Group Definition screen to display.
If, for example, the group number 14 has been assigned to the 724/735 channel port, group
number 14 appears next to Datagram Group Definition, and the channel port number is entered
in the Group Members field. Make sure you enter the appropriate group number and channel port
number for your configuration.
2-42
PARAMETER
SETTING
Channel Mode
Asynchronous
Channel Code
9600, 8 data bits, 1 stop bit, None
Flow Control
XON/XOFF
XON/XOFF Chars
Set 1: 11H/13H
ENQ/ACK Pacing
Inactive
Modem Controls
DCE (Local)
Echoplex
None
Flush on Break
Active
High Priority
Inactive
Slow Packetizing
Inactive
Info Messages
Inactive
August 1994
6800-A2-GB21-10