Connecting A Pc - Paradyne COMSPHERE 6800 Series Multiplexer Management And Configuration Manual

Network management system
Table of Contents

Advertisement

COMSPHERE 6800 Series Nework Management System
5. Create a communication link between the 719 NETWORKER and the terminal:
6. Go to Displaying the Configuration Menu.

Connecting a PC

Instead of a terminal, you can connect a PC to configure the 719 NETWORKER to communicate
with other multiplexers and the NMS host computer. However, a terminal emulator must be run on
the PC so that the PC can be used as an ASCII terminal. Two emulator programs are suggested: a
VT-100 terminal emulator (the other selection under SCX) and CTRM.
Make sure the following parameters are set on the PC:
You need an EIA RS-232 (DB-25) conductor cable to connect the PC to the 719 NETWORKER.
2-26
After the 444 appears, you have 15 seconds to press the
CONTROL MODE button and create a communication link (Step 5)
between the 719 NETWORKER and the terminal.
PRESS: CONTROL MODE
button on the front of the 719 NETWORKER. The system displays the following message
and prompt:
connected
(Node 0) menus (y/n)
VT-100 Emulator parameters
PARAMETER
Character Length
Stop Bits
Speed
Parity
Handshake
CTRM Emulator parameters (must be set in the ctrm.ini file)
PARAMETER
-s9600
-c8
-pn
1
August 1994
NOTE
SETTING
8 bits
1
9600 bps
None
XON/XOFF
SETTING
Speed = 9600 bps
Character length =
8 bits
Parity = None
Stop Bit = 1
6800-A2-GB21-10