Replacing The 10X 3.5-Inch Hdd Backplane - Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Hard disk drive (HDD) / solid state disk (SSD)
7.5.5

Replacing the 10x 3.5-inch HDD backplane

Field Replaceable Unit
(FRU)
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
"Locating the defective server" on page
▶ If applicable,
"Removing the front cover with lock" on page
"Shutting down the server" on page
"Disconnecting the power cord" on page
"Getting access to the component" on page
"Removing the fan cage" on page
▶ Release all HDD modules and pull them out a few centimeters, see
"Removing 3.5-inch HDD modules" on page
CAUTION
The HDD modules need not to be removed.
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶ Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page
Removing the defective 10x 3.5-inch HDD backplane
▶ If applicable, remove the internal RAID riser module, see
internal RAID riser module" on page
▶ Disconnect all cables from the HDD backplane.